Boron, Serum/Plasma Test (0711SP)
| Analysis Code |
0711SP |
| Test Name |
Boron, Serum/Plasma |
| Test Includes |
Boron [ICP/OES] |
| Compound Synonym(s) |
B |
| Purpose |
Exposure Monitoring/Investigation |
| Category |
Metal/Element |
| Method(s) |
Inductively Coupled Plasma/Optical Emission Spectrometry (ICP/OES) |
| Specimen Requirements |
2 mL Serum or Plasma |
| Transport Temperature |
Refrigerated |
| Specimen Container |
Plasma: Royal Blue top tube, plastic (Trace metal-free; EDTA), Serum: Royal Blue top tube, plastic (Trace metal-free; No additive) |
| Special Handling |
Promptly centrifuge and separate Serum or Plasma into an acid washed plastic screw capped vial using approved guidelines. |
| Light Protection Required |
Not Required |
| Stability |
Room Temperature: 30 day(s)
Refrigerated: 30 day(s)
Frozen (-20 °C): 30 day(s) |
| Rejection Criteria |
Glass container. Polymer gel separation tube (SST or PST). |
| Day(s) Test Set-up |
[ICP/OES] Monday Thursday 1 day |
| Suggested CPT Code |
[ICP/OES] 83018 |
You are viewing Boron, Serum/Plasma Test (0711SP)