Bromocriptine, Serum/Plasma Test (0751SP)
Analysis Code |
0751SP |
Test Name |
Bromocriptine, Serum/Plasma |
Test Includes |
Bromocriptine |
Purpose |
Therapeutic Drug Monitoring; This test is New York State approved. |
Category |
Parkinsonian Agent |
Method(s) |
High Performance Liquid Chromatography/ TandemMass Spectrometry (LC-MS/MS) |
Specimen Requirements |
2 mL Serum or Plasma |
Transport Temperature |
Frozen |
Specimen Container |
Plastic container (preservative-free) |
Special Handling |
Collect sample in Lavender top tube (EDTA). Promptly centrifuge and separate Serum or Plasma into a plastic screw capped vial using approved guidelines. |
Light Protection Required |
Yes |
Stability |
Room Temperature: Not Stable Refrigerated: 1 day(s) Frozen (-20 °C): 1 month(s) |
*Rejection Criteria |
Not received Light Protected. Received Room Temperature. Received Refrigerated. Polymer gel separation tube (SST or PST). |
Day(s) Test Set-up / TAT |
[LC-MS/MS] Wednesday / 4 days |
Suggested CPT Code |
80375 |
**Minimum Volume |
0.6 mL |
Test Summary Sheet |
Generate
 
|
You are viewing Bromocriptine, Serum/Plasma Test (0751SP)
*Rejection criteria pertain to clinical specimen submissions only.
**Stated minimum volume allows for a single analysis. Repeat analysis will not be performed.