Carbon Monoxide Exposure Biouptake Screen, Blood Test (1002B)

Analysis Code 1002B 
Test Name Carbon Monoxide Exposure Biouptake Screen, Blood 
Test Includes Carboxyhemoglobin [SP] 
Compound Synonym(s) COHb 
Purpose Exclusion Screen 
Category Biological Marker (Exposure) 
Method(s) Spectrophotometry (SP) 
Specimen Requirements 3 mL Blood 
Transport Temperature Refrigerated 
Specimen Container Lavender top tube (EDTA) 
Special Handling Collect sample at end of shift. 
Light Protection Required Not Required 
Stability Room Temperature: Undetermined Refrigerated: Undetermined Frozen (-20 °C): Undetermined 
Rejection Criteria None 
Day(s) Test Set-up [SP] Monday Wednesday Friday 1 day 
Suggested CPT Code [SP] 80101 
Reflex Testing
(when required, addl' fee may apply)
5654B - Carbon Monoxide Exposure Biouptake Confirmation, Blood 