Cholinesterase, Serum/Plasma Test (1256SP)
| Analysis Code |
1256SP |
| Test Name |
Cholinesterase, Serum/Plasma |
| Test Includes |
Cholinesterase [EZA] |
| Purpose |
Occupational Exposure Monitoring |
| Category |
Biological Marker (Exposure) |
| Method(s) |
Enzymatic Assay (EZA) |
| Specimen Requirements |
1 mL Serum or Plasma |
| Transport Temperature |
Refrigerated |
| Specimen Container |
Lavender top tube (EDTA) |
| Special Handling |
Promptly centrifuge and separate Serum or Plasma into a plastic screw capped vial using approved guidelines. |
| Light Protection Required |
Not Required |
| Stability |
Room Temperature: 7 day(s)
Refrigerated: 7 day(s)
Frozen (-20 °C): 7 day(s) |
| Rejection Criteria |
Polymer gel separation tube (SST or PST). |
| Day(s) Test Set-up |
[EZA] Friday 1 day |
| Suggested CPT Code |
[EZA] 82480 |