Methanol, Serum/Plasma Test (2834SP)

Analysis Code 2834SP 
Test Name Methanol, Serum/Plasma 
Test Includes Methanol [GC/MS] 
Compound Synonym(s) Methyl Alcohol Wood Alcohol 
Purpose Identification and Quantitation by GC/MS 
Category Environmental/Occupation Toxin 
Method(s) Gas Chromatography/Mass Spectrometry (GC/MS) 
Specimen Requirements 2 mL Serum or Plasma 
Transport Temperature Refrigerated 
Specimen Container Plastic container (preservative-free) 
Special Handling Collect sample using alcohol free skin preparation. Promptly centrifuge and separate Serum or Plasma into an plastic screw capped vial using approved guidelines. 
Light Protection Required Not Required 
Stability Room Temperature: 3 month(s) Refrigerated: 3 month(s) Frozen (-20 °C): 12 month(s) 
Rejection Criteria Polymer gel separation tube (SST or PST). 
Day(s) Test Set-up [GC/MS] Monday-Sunday 14 days 
Suggested CPT Code [GC/MS] 84600 